Tips for Proper Septum Handling to Minimize Degradation and Contamination

Tips for Proper Septum Handling to Minimize Degradation and Contamination

Aseptic Techniques | Pharmlabs

Personnel carrying out these procedures must use techniques to minimize the potential contamination (microorganisms, particulate material, pyrogens) possible during these manipulations. Aseptic Techniques can be defined as the sum total of methods and manipulations required to minimize the contamination of sterile compounded formulations.

Get Price
Tips for Proper Septum Handling to Minimize Degradation and Contamination

GC Injection Port Septa: Use, Maintenance, Storage and Handling

Routine Maintenance: To reduce the risk of leaks and contamination, injection port septa should routinely be replaced. Change the septum daily, especially if the instrument is in heavy use. Repeated use of the same septum may resultin increased coring, resulting in a leak.

Get Price
Tips for Proper Septum Handling to Minimize Degradation and Contamination

Preventing GC Septum Problems - standards.restek.com

Always use clean forceps, or wear clean powderless or cotton gloves when handling septa. Do not handle them with bare fingers or with powdered latex gloves—contaminants such as finger oils, perfumes, make-up, fingernail polish, skin creams, hand soaps, and talcum can be absorbed into the septum and will bleed out during your analyses.

Get Price
Tips for Proper Septum Handling to Minimize Degradation and Contamination

GC Troubleshooting Guide Poster - Aijiren

Feb 16, 2023 · Inlet contamination. Clean the inlet and replace liner, gold seal, and septum. Try a condensation test; gas lines may also need cleaning. Take steps to prevent sample . backflash (reduce injection volume, lower anlet temperature, use larger volume liner) Septum bleed Replace septum; Use a high-quality septum . appropriate for the inlet

Get Price
Tips for Proper Septum Handling to Minimize Degradation and Contamination

Quick Reference Guide to Troubleshooting Your Gas Chromatography

System contamination • Perform full injector port maintenance and replace consumables • Bake out column for 2 hours at maximum isothermal temperature • Perform full detector maintenance and replace consumables Inlet septum overheated • Ensure that your inlet septum is appropriately suited to your method temperature; replace if necessary

Get Price
Tips for Proper Septum Handling to Minimize Degradation and Contamination

Lithium ion battery degradation: what you need to know

Jan 25, 2021 · Battery degradation can be described using three tiers of detail. Degradation mechanisms describe the physical and chemical changes that have occurred within the cell. Mechanisms are the most detailed viewpoint of degradation but are also typically the most difficult to observe during battery operation.

Get Price
Tips for Proper Septum Handling to Minimize Degradation and Contamination

Stable isotope tracing to assess tumor metabolism in vivo

Sep 17, 2021 · In this protocol, we describe methods using stable isotopes to study cancer metabolism in mice and patients. The approach is informative and versatile, capable of studying tumors at many anatomic

Get Price
Tips for Proper Septum Handling to Minimize Degradation and Contamination

Proper Injection Technique to Prevent Coring - Innovation

Proper hand hygiene should be performed before handling medications, and the rubber septum should be disinfected with 70% isopropyl alcohol prior to piercing it and allow the alcohol to dry. To prevent coring, the needle should be inserted at a 45–60° angle with the opening of the needle tip facing up (i.e., away from the stopper), sometimes

Get Price
Tips for Proper Septum Handling to Minimize Degradation and Contamination

Safe Handling of Cannulas and Needles in Chemistry

Jan 5, 2022 · Cannulas and needles (sharps) are frequently used for chemical manipulations involving air- and moisture-sensitive chemicals. When using these devices, the presence of sharp tips poses a risk of puncture wounds and increases the likelihood of chemical exposure. While these devices are regularly used in chemistry, facts on their proper usage, as well as the prevention of injuries, are scarce in

Get Price
Tips for Proper Septum Handling to Minimize Degradation and Contamination

Tips and Tricks for the Lab: Air-Sensitive Techniques (3)

Jul 2, 2013 · Repeat steps 4 and 5 for flask 2. Purge the syringe by inserting the needle through the septum of the solvent flask and into the headspace of the flask. Draw up the inert atmosphere into the syringe. Remove the needle from the flask and expel the gas from the syringe (Fig. 14, D). Repeat 3–4 times.

Get Price
Tips for Proper Septum Handling to Minimize Degradation and Contamination

Preventing Septum Problems

Avoid extraneous peaks by proper septum handling & maintenance. Handy size chart & septum choice guidelines. Optimize performance by choosing the right septum for the job. Septum Handling All septa, regardless of their composition, puncturability, or resistance to thermal degradation, will be a source of

Get Price
Tips for Proper Septum Handling to Minimize Degradation and Contamination

Avoiding Contamination | Thermo Fisher Scientific - US

Centrifuges and vortexes are prone to contamination. You can significantly reduce contamination of work surfaces and equipment by cleaning them before and after qPCR using 70% ethanol.. Thorough cleaning is particularly important after a spill. Use a 10–15% bleach solution (sodium hypochlorite) for the best results, and remember to use gloves

Get Price
Tips for Proper Septum Handling to Minimize Degradation and Contamination

20.1.3: Mitigating Water Pollution - Biology LibreTexts

Maintaining or restoring riparian areas (riparian zones) is key to watershed management (figure 20.1.3.d 20.1.3. d ). These are areas of land close enough to a body of water to be affected by that body of water, for example, the lush region of vegetation surrounding a river. Riparian areas provide many ecosystem services that promote water

Get Price
Tips for Proper Septum Handling to Minimize Degradation and Contamination

14 Tips for a Successful RNA Extraction - US

Nov 5, 2021 · After quantification, aliquot your RNA into single-use tubes so that you can minimize freeze-thaw cycles (which can lead to degradation) or accidental RNase contamination. If you plan to use your RNA in the short term, store it at -20° C. Otherwise, store it at -80° C for longer-term storage.

Get Price
Tips for Proper Septum Handling to Minimize Degradation and Contamination

Best Practice for Identifying Leaks in GC and GC/MS Systems

The Aijiren septum nut has a C-shaped clip at the top that should not be turned more than 3/4 of a turn past where it begins turning with the nut assembly when a septum is being installed. Over tightening of the septum nut will cause premature septum coring with repeated injections, which in turn causes the septum to leak during a run. The

Get Price