Your position:
Home » News » lab vials » Standard opening hplc vials with caps for waters hplc

Standard opening hplc vials with caps for waters hplc

Material: USP Type 1, Class A, 33 Borosilicate Glass Volume: 2ml (standard volume) 1.5ml(actual volume) Application: HPLC and GC system Dimensions: 11.6 x 32mm Neck Diameter: 9mm Qty/Pack: 100pcs/pack Payment: T/T MOQ: 1pack
Share With:
Introduction

Certified Vials, Caps, Septa, and Inserts at Competitive Prices

• Cleaner vials eliminate ghost peaks and contaminants • Used with most autosamplers, including Aijiren ®, Thermo Scientific, and Waters® • Larger-opening “wide-mouth” style prevents broken needles and system downtime • Precision neck improves crimping Description 1000/pk Price Standard Opening

HPLC and GC Vials, Caps, Septas and Inserts Guide

2mL HPLC Clear Vials, Screw . Part 5 Autosamper Vial Product List (Bestsellers) 1. Screw 8-425 (8mm, N8) HPLC Vial, Cap, Septa and Inserts . They are made with a 5.5 mm opening. These vials are designed to work on most autosamplers that use 12mm x 32 mm crimp style vials.

LCGC Certified Amber Glass 12 x 32 mm – Waters Corporation

Waters Certified vials are tested for cleanliness by HPLC and held to tightest dimensional tolerances in the industry. LCGC Certified Amber Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk – 186000847C : Waters

8-425 Standard 1.5ml Lab Sample Amber Vials For Hplc

8-425 Standard 1.5ml Lab Sample Amber Vials For Hplc Autosampler -orchid Vials Screw Thread Septa Vials+black Caps+septa , Find Complete Details about 8-425 Standard 1.5ml Lab Sample Amber Vials For Hplc Autosampler -orchid Vials Screw Thread Septa Vials+black Caps+septa,Orchid Vials,Orchid Vials,Amber Vials from Laboratory Bottle Supplier or Manufacturer-Ningbo Excellent New Material Co., Ltd.

Hplc Vials by Zhejiang Aijiren Technology Co., Ltd. Supplier

Product Description V945 1.5mL Amber Screw Neck Vial w/Write-on Spot, 9-425 Thread, 11.6*32mm, USP type 1 Features 1)9mm screw vials can be used on all common autosampler 2)Standard narrow neck design for GC and HPLC 3)9mm wider opening for easy puncture 4)Clear, type 1 class A borosilicate glass 5)9mm PTFE/silicone septa, has excellent

Chromatography Vials | VWR

Description: Standard opening crimp-top vials have a maximum fill volume of 1.8 mL and are manufactured from inert, 33 expansion borosilicate glass. Certificates ,66020-953PK,66020-953CS,89239-004PK,89239-004CS,89239-006PK,89239-006CS,82028-402CS,82028-404CS

VWR Autosampler Vials, Inserts and Closures

2mL, 12x32mm, 8mm Standard Opening Screw Thread Vials and Inserts • 8-425 thread finish • Vials feature a write-on patch with graduation for convenient sample identification • Superior quality borosilicate glass • Polyspring inserts are self-aligning and provide a cushion against needle contact • Kits include 100 vials and 100 caps

Antibodies & Protein Biology – Fisher Scientific

Headspace vials are available in clear or amber glass with a round or flat base, a crimp seal with a beveled or square edge finish, or with a screw-thread finish. Headspace vials, septum, and caps can be purchased in various quantities separately or together as convenience kits to fit your laboratory needs.

HPLC Vials – GC – Storage – Orochem Technologies

Orochem Technologies offers vials for HPLC, GC and storage. The volume is from 0.1 mL to 4 mL. Both glass and plastic vials, with or without insert. There are several types of caps and septa.

China V935 Silicone Septa PP Cap Bottle Tubular Glass – China

2 ml 9-425 Shorter Screw Thread Vials with caps and septa ND9 Wider Opening. Performance : 1.Standard narrow neck design for GC and HPLC. 2. Optimal performance w/ Shimadzu, Varian, Hitachi 3. Our Standard vial is versatile and will also perform well with most instruments including Waters & Shimadzu ‘ s 4.

2ml amber and clear hplc vials for sale-Aijiren HPLC Vials

Choosing 2ml amber and clear hplc vials from Aijiren Tech.Aijiren is the leading supplier of 2ml clear and amber hplc vials since 2009 from China.

Generic HPLC 2ml vials ok to use in Acquity system? — Waters

We use pre-splitted vials. We already had a problem with an HPLC and its syringe with a non pre-splitted caps. From there, we use pre-splitted caps to ensure no needle problems. As it has already been written here, in UPLC there’s a first needle allowing to puncture the caps and then the needle that aspirate the sample comes out!

China HPLC Caps Manufacturers, Suppliers and Factory

1. Product Introduction. 1)Description. Caps for 9-425 vials,the most popular caps for autosampler vials, Open-Top Polypropylene Screw Thread Caps.Available with a large selection of cap colors and septa types.

What minimum volume of sample should be in a HPLC vial (2ml

Wit normal 2mL vials I would recomend between 150 and 250µL. Cite. 3 Recommendations. Reg. Hplc standard curve calculation. … High-performance liquid chromatography (HPLC) analysis method …

VIALS & CAPS – Lab

8 LABSOLUTE® VIALS & CAPS SCREW NECK ND8 SCREW NECK VIALS AND MICRO-VIALS ND8 Screw neck vials and micro-vials ND8 are used as standard in GC and HPLC. A large selection of micro-inserts is available for these vials. The micro-vials often require an adapter so that they can be used in the autosampler. Properties • 1st hydrolytic class glass

Inquiry
Please feel free to submit your inquiry information to us. We will contact with you as soon as possible.
Name:*
Country:
Email:*
Phone:
Inquiry:*