HPLC & GC Certified Vial Kits (Unassembled and Assembled) Catalog: Vial Glass: Patched: Cap: Septum: Vial / Closure Catalog: Pack of: Certified Convenience Kit (Unassembled) 9mm wide opening SureStop vials with AVCS caps; CERT5000-575W: 2mL Amber: Yes: Blue: Red PTFE/White Silicone: C5000-2W C5000-54B: 100: CERT5000-576W: 2mL Amber: Yes: Blue
Screw-top vials also come in different sizes, with vial caps made of either aluminum for crimp seals or plastic. Amber glass vials are available in 2-60 ml volume with a screw top. Inserts work in conjunction with any autosampler and fit either standard or wide openings vials.
ND15 8ml HPLC Vials. 15mm screw thread caps, septa, and vials are designed especially for use with Aijiren’s and other rotating or robotic arm samplers 8ml, 16.6X60mm vials are manufactured of Clear. Type 1 Class A or Amber, Type 1 Class B borosilicate glass
Standard opening screw thread vials contain a narrow opening allowing the use of GPI 8-425 closures and septa. This vial is designed to work in a variety of auto samplers requiring narrow neck vials. Available with graduated marking spots and silanized.
About 8mm (8-425) standard opening screw vials. 2mL, 12x32mm standard opening vials; 8-425 thread finish; Smaller opening (5mm ID) has less solvent contact with septum; Superior quality 1st hydrolytic class glass (Type 1) in clear and amber; Meets all requirements of Pharm. US, EU, JPN; Freezes well; Compatible with standard GC and HPLC
Vials. Vials are available in a variety of styles. Find autosampler vials, vial caps and closures, and vial inserts for chromatography with snap, screw, or crimp-top closures, with and without septa. Autosampler vials come in convenient pre-packaged sets.
Autosampler vials are available in a variety of neck finishes and opening diameters. Large mouth or wide ID vials have approximately a 40% wider mouth opening than standard opening vials. The large opening reduces the risk of bent autosampler needles during sampling. Screw thread vials and caps provide low evaporation, reusability, less hand
2)Standard narrow neck design for GC and HPLC. 3)9mm wider opening for easy puncture. 4)Clear, type 1 class A borosilicate glass. 5)9mm PTFE/silicone septa, has excellent chemical inertness, acid and alkali resistance. 6)9mm screw black open top pp cap. 1.5mL Clear Screw Neck Vial, 9-425 Thread, 11.6*32mm. Glass vial 2ml sample bottles
2 mL Standard Opening Vials from Supelco. Our standard 2 mL vial is 12 mm in diameter, 32 mm in height, and has a 4.6 mm opening. The thread size on this vial is 8-425. Choice of clear or amber glass. Precleaned or silanized options available
27261-U ; black polypropylene hole cap, thread for 8-425, PTFE/silicone, Top Hat (septa and closure designed to fit together tightly), for use with 2 mL vial, 4.6 mm opening, pkg of 100 ea
Thermo Scientific crimp top vials for HPLC and GC are available in 8mm, 11mm, or 13mm crimp border diameter in clear and amber glass and plastic. Microsampling options for small-sample-volume injections include one-piece microvials and standard inserts added to crimp top vials. Crimp vials are sealed with aluminum caps with septa using crimper
Thermo Scientific Routine Vials and Caps are ideal for use in most standard HPLC and GC applications and high-throughput analyses. These quality autosampler vials and caps provide consistent results for your standard and high-throughput pharmaceutical, environmental, and food and beverage applications.
The filter vial consists of two parts: a filter vial shell and a plunger which includes a single layer filter on one end and a vial cap on the other end. Applications for Standard Filter Vials include filtration of catalysts from organic and medicinal chemistry synthesis reactions, saccharide analysis in corn syrup, and in-vial protein
Alliance HT HPLC Systems. This vial delivers maximum sample capacity (~1.5 mL) with minimum residual volume. The 9 mm cap makes it ideal for use with Aijiren HPLC and GC Systems. Choosing the level of certified vial should be based on the concentration of analyte. Concentration of analytes is often tied closely with the detection source used.
cap, solvent bottle adapter and a combination inlet/sparge filter to eliminate the safety hazards of aluminum foil wrapped solvent containers. Solvent bottle adapter converts GL-45 mobile phase caps to standard 4 L solvent bottles for direct connection to an HPLC pump.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Application: Water analysis
Qty/Pack: 25pcs/pack or 100pcs/pack
Dimensions: 16 x 100mm
Neck Diameter: 16mm
Volume: 12ml
Payment: T/T
MOQ: 1 pack
Dimensions: 27.5 x 57mm/27.5 x 75mm/27.5 x 95mm/27.5mm x 140mm
Material: USP Type 1, Class A, 33 Borosilicate Glass
Application: Environmental analysis
Neck Diameter: 24mm
Qty/Pack: 100pcs/pack
Volume: 20-60ml
Payment: T/T
MOQ: 1 pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Dimensions: 16.6 x 60mm/18.5 x 65mm
Application: Environmental analysis
Neck Diameter: 15mm
Qty/Pack: 100pcs/pack
Volume: 8-12ml
Payment: T/T
MOQ: 1 pack
Material: Nylon; Hydrophilic PVDF; Hydrophilic PTFE; Hydrophobic PTFE; PES; MCE; Hydrophilic PP; Cellulose Acetate(CA)
Qty/Pack: 100pcs/pack
Application: Filter
Payment: T/T
MOQ: 1 pack