Vial, Closure and Septa Selection Guide. Use this as a guide to selecting the products you need. For technical assistance, contact Supelco Technical Service at (800) 359-3041 or e-mail us at techservice@sial.com.
Specifically designed for the bottom draw-port needle of the Waters ACQUITY UPLC and Alliance HT HPLC Systems. This vial delivers maximum sample capacity (~1.5 mL) with minimum residual volume. The 9 mm cap makes it ideal for use with Aijiren HPLC and GC Systems. Choosing the level of certified vial should be based on the concentration of analyte.
Aijiren vials and closures provide simple ways to boost laboratory productivity and return on investment. Aijiren premium certified vials, closures, high recovery vials, and vial inserts offer industry-leading performance; from the lowest bleed septum materials in our caps to the most inert glass vial materials, we are continuously refining our offerings by addressing small details delivering
11. Transfer a 3-mL aliquot of the sample solution from step 7 to a 4-mL vial. Cap the vial. 12. Inject a 20-µL sample aliquot. 13. Measure peak area or peak height. NOTE 1: If sample peak is larger than the largest standard peak, dilute an aliquot of the remaining sample solution, reanalyze, and apply appropriate dilution factor in the
1.10 Use clean vials, caps, and plates a. Use Waters-brand vials; they have been certified as contaminant-free.4 Other vials may not be clean or may have caps containing adhesives that can contaminate the sample manager. b. Make sure the liner on your vial and bottle caps does not contain contaminants (check the manufacturer’s description):
HPLC relies on pumps to pass a pressurized liquid and a sample mixture through a column filled with adsorbent, leading to the separation of the sample components. The active component of the column, the adsorbent, is typically a granular material made of solid particles ( e.g. , silica , polymers, etc.), 2–50 μm in size.
Adapter pack for MyFuge ™ 5 Microcentrifuge, holds 0.5-2.0 mL cryovials and 1.5/2.0 mL HPLC vials. 1 Product Result
Vials, Caps & Closures. At Kinesis, we appreciate the demands of today’s HPLC, LC/MSand GC analysis for quality, reliability and cleanliness. Our vials andclosures are designed to ensure contamination-free sample handling andtrouble-free autosampler operation.
Caps, Low Volume Inserts, Vials, U-2D Micro-sampling System & Vial Accessories for HPLC and GC are found in this category. Every chromatography laboratory has different requirements for sample containers, therefore, we have developed different “Tiers of Performance” to meet your specific needs. From our economical, BASIK™ tier of products, our MicroSolv™ pharmaceutical, grade b
Start here to get a free sample. Option 1: Enter your current part# to find the Phenomenex alternative or equivalent vial/cap Option 2: Choose the best vial for your system or your application
The flared end also makes the vial much stronger so that vials can easily be inserted and removed from the end of the probe using tweezers without breaking the glass. MS® caps and septa are available for different types of sample vials. Its vial products improve your laboratory productivity, by reducing costs and saving time. Sample Vial PDF
HPLC / GC autosampler vials, caps, septas, and inserts working as a whole to prevent sample degradation and loss of samples caused by evaporation. All components of autosampler vials from AirekaCells ® are designed manufactured by the same level of product standard.
Nonsterile or sterile vials are available in amber, white, or clear transparencies for effortless viewing. Open-top, closed-top, or screw-on caps styles may incorporate liners or pre-slit septas for easy specimen retrieval. Autoclavable sample vials designed for maximum recovery will eliminate liquid sample waste.
Metal-free Structure: (50-sample vial holder with 2 mL glass vials), or 96 (96-sample vial holder with 96-well microplate) … Return to the HPLC Instrument List …
Caps – Ordering Information; AQR™ screw and snap caps are the highest quality caps available with extremely low extractables & excellent resealing.. RSA™ Low Volume Vials & Inserts – Ordering Information; Maximum recovery vials including MRQ™, Max Recovery™ & “Fused Insert” vials and drop-in inserts with attached springs.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Application: Water analysis
Qty/Pack: 25pcs/pack or 100pcs/pack
Dimensions: 16 x 100mm
Neck Diameter: 16mm
Volume: 12ml
Payment: T/T
MOQ: 1 pack
Dimensions: 27.5 x 57mm/27.5 x 75mm/27.5 x 95mm/27.5mm x 140mm
Material: USP Type 1, Class A, 33 Borosilicate Glass
Application: Environmental analysis
Neck Diameter: 24mm
Qty/Pack: 100pcs/pack
Volume: 20-60ml
Payment: T/T
MOQ: 1 pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Dimensions: 16.6 x 60mm/18.5 x 65mm
Application: Environmental analysis
Neck Diameter: 15mm
Qty/Pack: 100pcs/pack
Volume: 8-12ml
Payment: T/T
MOQ: 1 pack
Material: Nylon; Hydrophilic PVDF; Hydrophilic PTFE; Hydrophobic PTFE; PES; MCE; Hydrophilic PP; Cellulose Acetate(CA)
Qty/Pack: 100pcs/pack
Application: Filter
Payment: T/T
MOQ: 1 pack