This application brief describes the use of a Quasar C18 column for the analysis of acetaminophen, aspirin and caffeine in accordance with the official Acetaminophen, Aspirin, and Caffeine Tablets USP monograph. Keywords: acetaminophen quasar lc columns quasar hplc columns quasar lc quasar hplc lc columns hplc columns asprin caffeine
Nov 28, 2015 · Autosampler vials must be correctly chosen to be compatible with the injector used, contain an excess of liquid and have a loose cap to prevent evaporation or a vacuum from forming inside the vial. *Test injector accuracy and reproducibility separately, at the volume used for your analysis, as part of your method development review.
Modern HPLC systems have been improved to work at much higher pressures, and therefore are able to use much smaller particle sizes in the columns (<2 μm). These "ultra high performance liquid chromatography" systems or UHPLCs can work at up to 120 MPa (17,405 lbf/in 2), or about 1200 atmospheres.
LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, Total Recovery, with Cap and Preslit PTFE/Silicone Septum, 1 mL Volume, 100/pk. As a leading manufacturer of analytical instrumentation and consumable products, Waters knows how important it is to choose autosampler vials that enhance the performance of your other instrumentation.
There’s a Thermo Scientific screw top vial for every HPLC, GC, MS instrument, application, and budget. Our screw top clear and amber glass vials and plastic screw top vials are available in 8mm, 9mm, 10mm, and 13mm screw threads. The most commonly used vials are 9mm, 12x32mm screw thread vials.
Jul 18, 2014 · 2014 •red HPLC / GC / Chromatography vials and caps 1. www.dot-red.com Vials and ClosuresVials and Closures 2. www.dot-red.com red® About the BrandAbout the Brand red® is the new name in quality engineered and manufactured products. red® branded products are available to customers worldwide through a network of officially appointed dealers red® branded products are supported by full
Polypropylene certified vials for autosampler use are translucent and chemically resistant. They are the vials of choice for pH-sensitive samples, sodium, or heavy metal analyses. Polypropylene vials come in snap, crimp, or screw styles and can contain sample volumes up to 700 µL while leaving minimum residual volumes of less than 3 µL.
13-425 4ml Sample Vials. 13-425 screw thread caps, septa, and vials are designed for specific use with the Waters WISP 48-Position Autosampler. Vials are manufactured of Clear, Type 1 Class A or Amber, Type 1 Class B borosilicate glass and include a write-in patch for sample identification
the vial appropriate for your application.) Other vials can contain contaminants that interfere with the application and contaminate the system. 2. Make sure the liner on your vial and bottle caps does not contain contaminants (check the manufacturer’s description): • Do not use vials or bottle caps lined with paper. Paper can be a source of
PEEK rotor seal for use on Aijiren 1200 SL autosamplers. Designed to work with all 1200 series 600 bar systems (1200 SL G1329B, 1220 Infinity, 1260 Infinity), this alternative part represents a significant cost saving to the OEM.
HPLC ACCESSORIES AND SUPPLIES. From high-quality fittings and tubing, to solvent and waste containment options, Chrom Tech offers a variety of HPLC accessories that provide solutions for all your chromatography needs. We carry HPLC accessories and components for a wide range of applications that require precise and accurate results.
27261-U ; black polypropylene hole cap, thread for 8-425, PTFE/silicone, Top Hat (septa and closure designed to fit together tightly), for use with 2 mL vial, 4.6 mm opening, pkg of 100 ea
Waters also offers a selection of glass sample vials and plastic sample vials that fit most manufacturers’ instruments. Two of the most popular uses are as HPLC vials and GC vials. These chromatography vials can be used as sample storage vials by adding a solid caps with liner.
1.5mL 8-425 Screw Neck Vial ND8 1.5mL 9mm Short Thread Vial ND9 1.5mL 10-425 Screw Neck Vial ND10 1.5mL 11mm Snap Ring Vial ND11 1.5mL 11mm Crimp Ring Vial ND11 4mL 13-425 Screw Neck Vial ND13 1mL Shell Vial Micro Insert for for 2mL HPLC vials Vial Racks Hand Crimper, Decrimper
How to identify, isolate, and correct the most common HPLC problems. Although HPLC method development has been improved by advances in column technology and instrumentation, problems still arise. In this guide we offer you a systematic means of isolating, identifying, and correcting many typical HPLC problems.
Material: USP Type 1, Class A, 33 Borosilicate Glass
Application: Water analysis
Qty/Pack: 25pcs/pack or 100pcs/pack
Dimensions: 16 x 100mm
Neck Diameter: 16mm
Volume: 12ml
Payment: T/T
MOQ: 1 pack
Dimensions: 27.5 x 57mm/27.5 x 75mm/27.5 x 95mm/27.5mm x 140mm
Material: USP Type 1, Class A, 33 Borosilicate Glass
Application: Environmental analysis
Neck Diameter: 24mm
Qty/Pack: 100pcs/pack
Volume: 20-60ml
Payment: T/T
MOQ: 1 pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Dimensions: 16.6 x 60mm/18.5 x 65mm
Application: Environmental analysis
Neck Diameter: 15mm
Qty/Pack: 100pcs/pack
Volume: 8-12ml
Payment: T/T
MOQ: 1 pack
Material: Nylon; Hydrophilic PVDF; Hydrophilic PTFE; Hydrophobic PTFE; PES; MCE; Hydrophilic PP; Cellulose Acetate(CA)
Qty/Pack: 100pcs/pack
Application: Filter
Payment: T/T
MOQ: 1 pack