Your position:
Home » News » lab vials » Common use amber vials and caps for liquid autosampler

Common use amber vials and caps for liquid autosampler

Material: USP Type 1, Class A, 33 Borosilicate Glass Volume: 2ml (standard volume) 1.5ml(actual volume) Application: HPLC and GC system Dimensions: 11.6 x 32mm Neck Diameter: 9mm Qty/Pack: 100pcs/pack Payment: T/T MOQ: 1pack
Share With:
Introduction

GUIDELINES FOR AUTOSAMPLER VIAL SELECTION

Autosampler vials may seem insignificant when compared to the sophisticated analytical instrumentation most laboratories use, but the incorrect vial, cap or septa can contribute to problems that can decrease productivity and reproducibility. Potential Problems Caused by Using Incorrect Vial/Cap/Septum: • Loss of analyte due to evaporation

Products – Fisher Sci

Autosampler vial closures include plugs, snap caps, septa, screw caps and crimp caps recognized for quality, reliability, and consistency. Autosampler Vial Screw Caps Screw caps provide an inert, airtight seal and direct puncture-access to samples with a syringe needle.

Vials | Products | GL Sciences

Vials for Autosamplers Vials. GL Sciences’ economic vials for autosampler can be used on all common autosamplers due to their technical geometry. Using these universally compatible vials, rationalization of other 2 mL vials, as for instance 11 mm crimp neck vials, screw neck vials 8 – 425 and 10 – 425, is possible.

Routine Autosampler Vials | Thermo Fisher Scientific – US

Thermo Scientific Routine Vials and Caps are ideal for use in most standard HPLC and GC applications and high-throughput analyses. These quality autosampler vials and caps provide consistent results for your standard and high-throughput pharmaceutical, environmental, and food and beverage applications.

GUIDELINES FOR AUTOSAMPLER VIAL SELECTION

Autosampler vials may seem insignificant when compared to the sophisticated analytical instrumentation most laboratories use, but the incorrect vial, cap or septa can contribute to problems that can decrease productivity and reproducibility. Potential Problems Caused by Using Incorrect Vial/Cap/Septum: • Loss of analyte due to evaporation

Glass Vials, Dram Vials – Huge Selections – Premium Vials

1/4 Dram Amber Glass Vial – w/Orifice Reducer & Black Cap GV038 $20.88 These glass vials are great for holding small amounts of liquid and samples of essential oils, floral waters, perfumes, and more.

Aijiren amber EPA water analysis vials for autosampler use

High Recovery 2ml Autosampler Aer Vials for Lab The crimped top Autosampler Vials is the most commonly used gas sampling vials on the market today.The Autosampler Vials with a volume of 2ml is especially suitable for practical use in experiments.At the same time, some Autosampler Vials bottom plates are designed as round bottom plates, making the bottom plate flat and compatible with

Common use amber gas chromatography vials for wholesales USA

GL Sciences’ economic vials for autosampler can be used on all common autosamplers due to their technical geometry. Using these universally compatible vials, rationalization of other 2 mL vials, as for instance 11 mm crimp neck vials, screw neck vials 8 – 425 and 10 – 425, is possible. 1030-10002 1.5 mL 32 x 11.6 mm Clear Glass 9-425 Thread

Thermo Scientific 20 mm Headspace Vials, Septum, and Caps

Thermo Scientific™ headspace vials are available in clear or amber glass with a round or flat base, a crimp seal with a beveled or square edge finish, or with a screw-thread finish. Headspace vials, septum, and caps can be purchased in various quantities separately or together as convenience kits to fit your laboratory needs. Ordering

Thermo Scientific 11mm Amber Glass Crimp/Snap Top Vials Amber

For use with snap caps or aluminum crimp seal closures, these high-quality 11mm amber glass vials are 2mL, 12x32mm and fit most brands of autosamplers. Made of superior quality 51A (Type 1, Class B), they meet all requirements of US, EU, JPN Pharmacopia.

Thermo Scientific Shell Vials Amber Glass; SepCap; 1mL

These neckless vials with inserts are sold as kits including polyethylene push in caps to assure proper fit and function. Vial selections include clear glass, amber glass or polypropylene. 8x35mm shell vials are designed specifically for Alcott Positive Displacement autosamplers. Choose from Thermo Scientific™ National™ and Chromacol™ brands.

Vials – Fisher Sci

Fisher Scientific SAS – Boulevard Sébastien Brant – F67403 Illkirch Cedex – France Tél. 03 88 67 14 14 – Fax. 03 88 67 11 68 – fr.fisher@thermofisher.com

Routine Autosampler Vials | Thermo Fisher Scientific – KR

Thermo Scientific Routine Vials and Caps are ideal for use in most standard HPLC and GC applications and high-throughput analyses. These quality autosampler vials and caps provide consistent results for your standard and high-throughput pharmaceutical, environmental, and food and beverage applications.

Autosampler Vials – Fisher Scientific

Autosampler Vials, Caps, and Closures Thermo Scientific™ 9mm Clear Glass Screw Thread Vials Nearly eliminate septa push-through and improve sealing with vials built with the innovative Advanced Vial Closure System (AVCS).

Common use amber gc headspace vials with high quality USA

Our portfolio consists of GC vials and LC vials, GC caps and LC caps, and GC septa and LC septa. Through our biological line, we offer glass and plastic vials for optimal measurement of samples by liquid scintillation counting. Our glass vials are chemically-inert, making them suitable for use with aggressive reagents and solubilizers.

Inquiry
Please feel free to submit your inquiry information to us. We will contact with you as soon as possible.
Name:*
Country:
Email:*
Phone:
Inquiry:*