Tray for 100 × 2-ml vials G1313-44500 Halftray for 15 × 6-ml vials G1313-44503 Halftray for 40 × 2-ml vials G1313-44502 Spring G1313-09101 Spring stud 0570-1574 Tray base for G1313A (includes items 4, 5). G1313-60002 Figure 28 Vial Trays and Tray Base
2. Personal sampling pump, 0.03 to 1.5 L/min with flexible connecting tubing. 3. Vials, 4-mL, glass with PTFE-lined rubber septa caps. 4. Vials, 20-mL, glass. NOTE: Do not use vials with “polycone” liners (sources of high formaldehyde blanks)[5,9].
Where k* is the average gradient retention, ΔΦ is the change in %B (5% – 95% B = 0.9 for this equation), V m is the column interstitial volume (π x radius 2 x length x 0.6) and F is the flow rate (mL/min.). So for a 50 x 2.1mm column at 0.2 mL/min and a gradient of 5 – 95% B, to obtain a k* value of 3 the gradient time would need to be;
HPLC autosampler vials are used for injecting samples from an autosampler. They come in various sizes, even though 2 mL vials are the most common ones used. Autosampler needle pierces through the cap during injection and withdraws the required aliquots of sample from the vials.
4ml Sampling Vials Hplc Vials. , Find Complete Details about 4ml Sampling Vials Hplc Vials.,4ml Sampling Vials,4ml Vials,Sampling Vials from Laboratory Bottle Supplier or Manufacturer-Zhejiang Aijiren Technology Inc.
Feb 14, 2013 · Caps & Septa for 2.0 mL, 8 mm Screw-Thread Vials Description Black Polypropylene, Open-Hole Caps Septa, 8 mm x 0.045″ Septa, 8 mm x 0.065″ Septa Material. 100-pk. Red PTFE/Silicone Red PTFE/White
Nov 14, 2016 · MACHEREY-NAGEL Vials and caps for. GC and HPLC. Environmental analysis (TOC/VOC) Firmly integrated 0.2 mL glass insert in plastic outer shell … Crimp neck vials N 8 For micro sampling. 70286 …
These vials are recommended for short term sample storage and non-volatile samples because the seal is not as secure as a crimp or screw thread seal. Shell Vials are an economical alternative to screw thread vials for Water’s HPLC autosamplers or any other autosampler that doesn’t use a robotic arm to move the vials.
Common Features flexibly Adapts To A Variety Of Applications * Sample Vials Ranging From Microtiter Plates To 13ml Vials Are Supported*, And Can Be Used In A Wide Range Of Applications From Analytical To Semi-preparative Work. * Syringe Measured Display Type: Digital Numerical Display; For use with HPLC: Yes; Injection Style: Vials, Wellplate
1)9mm screw vials can be used on all common autosampler. 2)Standard narrow neck design for GC and HPLC. 3)9mm wider opening for easy puncture. 4)Clear, type 1 class A borosilicate glass. 5)9mm PTFE/silicone septa, has excellent chemical inertness, acid and alkali resistance. 6)9mm screw black open top pp caps
1)9mm screw vials can be used on all common autosampler . 2)Standard narrow neck design for GC and HPLC. 3)9mm wider opening for easy puncture. 4)Clear, type 1 class A borosilicate glass. 5)9mm PTFE/silicone septa, has excellent chemical inertness, acid and alkali resistance. 6)9mm screw black open top pp cap
PTFE-lined caps 10. Tubes, polypropylene, disposable screw-top, 15 mL. Polypropylene bottles and caps may also be used for sample collection. 11. Metal spatula 12. Volumetric flasks: 10, 50, 100 and 200 mL 13. Autosampler vials, amber, with caps and septa 14. Disposable glass pipets 15. Sintered glass filtration apparatus and 1-L side- armed
Sep 02, 2016 · TOC testing typically requires 30-40 mL of purified water for extraction based upon the sampling needs of the instrument. For HPLC testing, the extraction solvent requirements are far less. For a single small swab head, the minimum volume can be as little as 2 mL, although typical extraction volumes are in the 5-10 mL range.
caps and septa screw thread vials that are supplied in a storage tray. Vials have a wide opening, 2 mL capacity and measure 12 x 32 mm. Vials are supplied ready to use saving time and labor. Trays are stackable for easy storage and hold vials upright for filling and maintaining sample order.
Qualyvials 1.5 are glass 1.5 ml vials suitable for all common HPLC and GC autosamplers. The septa are coated on one side with PTFE, which ensures chemical stability. They are also available with self-sealing polyethylene caps for sample storage (SS series).
Material: USP Type 1, Class A, 33 Borosilicate Glass
Application: Water analysis
Qty/Pack: 25pcs/pack or 100pcs/pack
Dimensions: 16 x 100mm
Neck Diameter: 16mm
Volume: 12ml
Payment: T/T
MOQ: 1 pack
Dimensions: 27.5 x 57mm/27.5 x 75mm/27.5 x 95mm/27.5mm x 140mm
Material: USP Type 1, Class A, 33 Borosilicate Glass
Application: Environmental analysis
Neck Diameter: 24mm
Qty/Pack: 100pcs/pack
Volume: 20-60ml
Payment: T/T
MOQ: 1 pack
Material: USP Type 1, Class A, 33 Borosilicate Glass
Dimensions: 16.6 x 60mm/18.5 x 65mm
Application: Environmental analysis
Neck Diameter: 15mm
Qty/Pack: 100pcs/pack
Volume: 8-12ml
Payment: T/T
MOQ: 1 pack
Material: Nylon; Hydrophilic PVDF; Hydrophilic PTFE; Hydrophobic PTFE; PES; MCE; Hydrophilic PP; Cellulose Acetate(CA)
Qty/Pack: 100pcs/pack
Application: Filter
Payment: T/T
MOQ: 1 pack